Features:
1. Convert AC input selected by switch
2. Protection: Over voltage, over current, short circuit protection
3. Heat from the cold
4. 100% full-load burn-in test
5. Installation Guide: TS-35/7.5 or TS-35/15
6. High quality and low price
Specification:
Model number | DR-120-12 | DR-120-24 | DR-120-48 |
DC Output Voltage | 12V | 24V | 48V |
Output Voltage Error | ± 2% | ± 1% | ± 1% |
Rated Output Current | 10A | 5A | 2.5A |
Output Current Range | 0-10A | 0-5A | 0-2.5A |
Ripple and Noise | 80mVp-p | 80mVp-p | 100mVp-p |
Inlet Stability | ± 0.5% | ± 0.5% | ± 0.5% |
Load Stability | ± 1% | ± 1% | ± 1% |
DC Output Power | 120W | 120W | 120W |
Efficiency | 80% | 84% | 85% |
Adjustable Range for DC Voltage | ± 10% | ± 10% | ± 10% |
AC Input Voltage Range | 88~132VAC/176~264VAC 47~63Hz; 248~370VDC | ||
Input Current | 2.6A/115V 1.6A/230V | ||
AC Inrush Current | Cold-Start Current 25A/115V 45A/230V | ||
Leakage Current | <3.5mA/240VAC | ||
Overload Protection | 105%~150% Type: Cut Output, Reset: Auto Recovery | ||
Over Voltage Protection | 15~17V | 29~33V | 58~62V |
High-temperature Protection | 85°C±5°C(TSW1) | 90°C±5°C(TSW1) | 90°C±5°C(TSW1) |
Temperature Coefficient | ± 0.03% /°C (0~50°C) | ||
Start, Rise, Hold time | 500ms, 70ms, 36ms | ||
Vibration | 10~500Hz, 2G 10min/1 cycle, a total of 60 minutes, Each axes | ||
Withstand Voltage | Input and Output Interval: 1.5KVAC, Input and Enclosure: 1.5KVAC, Output and Enclosure: 0.5KVAC | ||
Isolation Resistance | Input and Output Interval: Input and Enclosure, Output and Enclosure: 500VDC/100M Ohms | ||
Working Temperature and Humidity | -10°C~+60°C, 20%~90%RH | ||
Dimension | 125.2*65.5*100 mm | ||
Weight | 0.8kg |
Dimension unit:mm