Add to Cart
Single output Switching Power Supply 24V 200W 8.5A 110V or 220V input AC to DC
Features:
1. Reliable quality and good price
2. High efficiency and low working temperature
3. Built-in EMI filter
4. 100% full-load burn-in test
5. Protection: Over load protection, short circuit protection
Specification:
Model number | S-200-5 | S-200-12 | S-200-15 | S-200-24 | S-200-48 |
DC Output Voltage | 5V | 12V | 15V | 24V | 48V |
Output Voltage Error | ± 2% | ± 1% | ± 1% | ± 1% | ± 1% |
Rated Output Current | 40A | 16.5A | 13.3A | 8.5A | 4.2A |
Output Current Range | 0-40A | 0-16.5A | 0-13.3A | 0-8.5A | 0-4.2A |
Ripple and Noise | 75mVp-p | 75mVp-p | 75mVp-p | 75mVp-p | 75mVp-p |
Inlet Stability | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% |
Load Stability | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% |
DC Output Power | 200W | 198W | 200W | 200W | 200W |
Efficiency | 80% | 84% | 84% | 85% | 86% |
Adjustable Range for DC Voltage | 4.74-5.5V | 10.8-13.2V | 13.5-16.5V | 21.6-26.4V | 43-53V |
AC Input Voltage Range | 90~132VAC/180~264VAC (selected by switch), 47~63Hz, 248~370VDC | ||||
Input Current | 3.2A/115V 1.6A/230V | ||||
AC Inrush Current | Cold-Start Current: 25A/115V, 50A/230V | ||||
Leakage Current | <3.5mA/240VAC | ||||
Overload Protection | 105%~150% Type: Cut Output, Reset: Auto Recovery | ||||
Over Voltage Protection | 115%~135%VO | ||||
Temperature Coefficient | ± 0.03% /°C (0~50°C) | ||||
Start, Rise, Hold time | 200ms, 100ms, 20ms | ||||
Vibration | 10~500Hz, 2G 10min/1 cycle, a total of 60 minutes, Each axes | ||||
Withstand Voltage | Input and Output Interval: 1.5KVAC, Input and Enclosure: 1.5KVAC, Output and Enclosure: 0.5KVAC | ||||
Isolation Resistance | Input and Output Interval: Input and Enclosure, Output and Enclosure: 500VDC/100M Ohms | ||||
Working Temperature and Humidity | -10°C~+60°C (Refer to Output Derating Curve), 20%~90%RH | ||||
Dimension | 199*110*50 mm | ||||
Weight | 0.9kg | ||||
Safety Standards | Meet UL 1012 requirement (Not apply for the mark) | ||||
EMC Standards | Meet FCC Part 15J Condition class A |
1. The testing condition for the parameter above is: 230VAC input, rated load, 25°C 70%RH, Temperature .
2. Error, include the setting error, line stability and load stability.
3. Wave test: adopting "A12" twisted pair wire for 20MHz, and 0.1uF-47uF capacitor short-circuit for interrupting .
4. Inlet Voltage Stability test: when it is over load, the lowest voltage of inlet is representative to the highest voltage .
5. Load stability test: the load is from 0% to 100% .
Dimension unit:mm